Products
REF 306-P
TRACOE twist Tracheostomy Tube,Unfenestrated
« backforward »In sterile package,
order-no.: REF 306-P
- Outer cannula with cuff and subglottic suction line
- 2 Inner cannula with 15 mm connector
- 2 connectors for suction devices
- Atraumatic inserter
- Reinsertion tube
- Sterile lubricating gel
- Perforated obturator and wide neck strap
The Innovation
The Feature of the TRACOE experc Set twist is the Atraumatic Insertion System of the Tubes. Its tip has a folding silicone sleeve that smoothly bridges over the gap in diameter between the inserter and the end of the tube.
The inserter also excels with a precise fit into the tube and a stop at the 15 mm conector. Once the tube is in the trachea, the inserter is pulled out of the tube. In doing so the silicone sleeve flaps back to facilitate its easy removal.
The Benefits
- Dilation is performed using the Ciaglia one-step technique.
- The atraumatic inserter smoothes over the gap in diameter between the end of the tube and the inserter. This minimizes the risk of injury when inserting the tracheostomy tube into the trachea.
- The stop at the15 mm conector prevents the inserter from being inserted too far into the tube, which additionally reduces the risk of injury.
- The separately available tubes with insertion system can also be used for reinsertion into a percutaneously created tracheostoma and/or change tubes; if necessary in combination with the Seldinger guide wire.
-
Each tube is supplied with
perforated obturator and a wide adjustable neck strap as well as a tube info card with peel-off stickers on front and back. The neck strap is also available
separately (REF 903-F).

REF 306.P, fenestrated
As a product variant REF 306-P is also available fenestrated.
technical data TRACOE twist Tracheostomy Tube,Unfenestrated**
| Size | REF-No. | Units/Package | ID-IK | AD-AK ke | AD-AK hs | Länge TL | Länge OB | BW | MD |
|---|---|---|---|---|---|---|---|---|---|
| Pck. | mm | mm | mm | mm | ° | mm | |||
| 07 | REF 306-07-P | 1 | 7,0 | 10,4 | 12,0 | 74 | 80,5 | 95 | 24 |
| 08 | REF 306-08-P | 1 | 8,0 | 11,4 | 12,7 | 76 | 83,0 | 90 | 28 |
| 09 | REF 306-09-P | 1 | 9,0 | 12,5 | 14,2 | 78 | 88,5 | 90 | 30 |
|
ID-IK: inside diameter (clear width) at bottom of inner cannula |
|||||||||
technical Overview
* Images may differ from original.
** Technical modifications and errors excepted.
download catalogue
TRACOE medical GmbH
Reichsforststr 32
60528 Frankfurt/Main
Phone: +49 (0)69 - 665 668-0
Fax: +49 (0)69 - 665 668-10
E-Mail: info@tracoe.com